SCALANCE XF-200 switches

  • Ordering data

  •  

  • Accessories

  • Product Information

Jump to

Overview

Benefits

Application

Design

Function

Technical specifications

More information

Overview河南西门子PLC总代理

The managed Industrial Ethernet switches of the SCALANCE XF-200 line are optimized for setting up Industrial Ethernet networks at data transmission rates of 10/100 Mbps in a line, star or ring topology.

  • Integrated redundancy manager for constructing Fast Ethernet ring topologies with fast media redundancy

  • Electrical or optical connection to stations or networks according to port characteristics of the devices

  • Enclosure in SIMATIC ET 200S format (slim design) for use in small control boxes

  • Rugged station connections with industry-standard RJ45 connectors that offer additional strain and bending strain relief thanks to latching on the enclosure

  • PROFINET diagnostics, SNMP access, integrated web server and automatic email transmission function for remote diagnostics and signaling via the network

  • Integration into the SINEC NMS network management system for end-to-end network diagnostics with central firmware management

Product variants河南西门子PLC总代理

  • Switches with electrical and optical ports for glass multimode FOC up to 5 km:

    • SCALANCE XF204-2
      4 x 10/100 Mbps RJ45 port, electrical
      2 x 100 Mbps ST/BFOC port, optical

    • SCALANCE XF206-1
      6 x 10/100 Mbps RJ45 port, electrical
      1 x 100 Mbps ST/BFOC port, optical

  • Switches with electrical ports:

    • SCALANCE XF204;
      4 x 10/100 Mbps RJ45 port, electrical

    • SCALANCE XF208;
      8 x 10/100 Mbps RJ45 port, electrical

Benefits河南西门子PLC总代理

  • Saves space in the control cabinet and uses smaller control boxes due to slim design in the format of the SIMATIC ET 200S distributed I/O

  • Simple connection and disconnection of the RJ45 plug by means of easily accessible RJ45 sockets angled downward on the device

  • High availability of the network thanks to:

    • Redundant power supply

    • Redundant network structures based on fiber-optic or twisted-pair cables (redundancy manager is integrated)

    • Easy device replacement by means of C-plug removable data storage medium

  • Lower susceptibility to failure and higher availability of the plant networking due to latching of the RJ45 FastConnect connectors in the securing collar of the RJ45 ports

  • Protection of investment through integration into existing network management systems (e.g. SINEC NMS), by means of standardized SNMP access

  • Time savings during engineering, commissioning and in the operating phase of a plant by using the configuration and diagnostics integrated in STEP 7/TIA Portal

河南西门子PLC总代理

Application

SCALANCE XF-200 Industrial Ethernet switches enable cost-effective configuration of Industrial Ethernet line, star or ring topologies with switching functionality for networks in which high availability or remote diagnostic capabilities are required. Devices with IP20 degree of protection are designed for use in the control cabinet.

Features:

  • Device diagnostics with LEDs (power, link status, data communication)

  • Remote diagnostics by means of signaling contact, PROFINET, SNMP or SINEC NMS and web browser possible

  • The RJ45 sockets are designed to be industry-compatible with additional securing collars for connection of the IE FC RJ45 plug 180

Design河南西门子PLC总代理

The SCALANCE XF-200 managed Industrial Ethernet switches are designed for installation on a standard DIN rail. With their enclosure in SIMATIC ET 200S format (slim design), the devices are optimally suited for integration in automation solutions in small control boxes together with the SIMATIC ET 200S.

The switches with IP20 degree of protection feature:

  • A 4-pin terminal block for connecting the redundant supply voltage (2 x 24 V DC)

  • A row of LEDs to indicate the status information (power, link status, data traffic, power supply, signaling contact)

  • A 2-pin terminal block for connecting the floating signaling contact

  • A SET button for on-site configuration of the signaling contact

The SCALANCE XF-200 switches are available with the following port types:

  • 10/100BaseTX, RJ45 connection;
    RJ45 socket, automatic detection of the data rate (10 or 100 Mbps), with autosensing and autocrossover functions for connecting IE FC cables using the IE FC RJ45 Plug 180.

  • 100BaseFX, ST/BFOC connection technology;
    ST/BFOC sockets for direct connection to Industrial Ethernet glass fiber-optic cables up to 5 km (multimode FOC) for configuring line, ring, and star topologies.

Function

  • Setup of electrical and optical Industrial Ethernet line, star and ring topologies

  • Fast redundancy in the ring with High Speed Redundancy (HRP) protocol; up to 0.3 seconds for reconfiguration of the ring with 50 switches in the ring

  • Fast redundancy in the ring with PROFINET-compliant Media Redundancy Protocol (MRP); max. 0.2 seconds required for reconfiguration of the ring with 50 switches in the ring河南西门子PLC总代理

  • The functioning of the ring is continuously monitored by the integrated redundancy manager. It recognizes failure of a transmission link in the ring, or failure of a SCALANCE XF-200, and activates the substitute path within 0.3 or 0.2 seconds

  • Use in ring topologies (100 Mbps) together with SCALANCE XR-500, XM-400, X-300 and X-200

  • Uncrossed connecting cables can be used due to autocrossover function integrated in the ports

  • Load disconnection through integral switch functionality

  • Easy diagnostics using signaling contact, SNMP and web browser

  • Easy copper cable diagnostics via web browser for localizing cable breaks

  • Incorporation in the integrated system diagnostics of the TIA Portal with PROFINET diagnostics for a consistent diagnostics concept, including network infrastructure

  • Diagnostics of data traffic by means of a parameterizable mirror port with a standard commercially available network analyzer (e.g. via Bus Analyzer Agent XM-400)

  • Fast device replacement in the event of a fault by using the optional C-plug removable data storage medium (not included in scope of delivery)

Network topology and network configuration

The SCALANCE XF-200 Industrial Ethernet switches with IP20 degree of protection are usually installed in a control cabinet together with the stations to be connected. Electrical and optical versions can be installed together in star, line and ring topologies.

When configuring the netwo河南西门子PLC总代理rk, the following boundary conditions must be observed:

  • Length of the twisted pair line between two SCALANCE XF-200 switches

    • Max. 100 m with IE FC cable and IE FC RJ45 plug 180

    • Max. 10 m using patches with TP cord

  • Length of the optical cables

    • Max. 5000 m with Industrial Ethernet glass fiber-optic cables (multimode)

  • IP address:河南西门子PLC总代理
    The IP address is assigned by means of the DHCP (Dynamic Host Configuration Protocol). If there is no corresponding server in the network, the IP address can be assigned using the supplied software tool PST (Primary Setup Tool) or STEP 7/TIA Portal. The SCALANCE XF-200 switches are configured with STEP 7/TIA Portal.

Commissioning and diagnostics

PROFINET diagnostic interrupts from SCALANCE XF-200 switches can be displayed with the appropriate SIMATIC engineering tools and processed in the PLC with an expanded diagnostics function. The engineering outlay for the PLC and HMI has been drastically reduced due to the complete integration in the SIMATIC concept for system error messages.河南西门子PLC总代理

SCALANCE XF-200 Industrial Ethernet switches can also be integrated in a network management system (e.g. SINEC NMS) using the standardized Simple Network Management Protocol (SNMP). In the event of faults in the device, error messages (SNMP traps) can be sent to a network management system (e.g. SINEC NMS) or as an email to a specified network administrator.

The integrated web server enables configuration and diagnostics settings to be made using a standard web browser (e.g. port configuration). Statistical information can also be read out over the web server (e.g. port capacity utilization).

The following information is displayed on site by LEDs:

  • Power

  • Port status

  • Data traffic

  • Signaling contact

  • Redundancy manager function

The Industrial Ethernet switches of the SCALANCE XF-200 line can also be monitored using the floating signaling contact.

河南西门子PLC总代理

Technical specifications2527598909.jpg

Article number6GK5204-0BA00-2AF26GK5204-2BC00-2AF26GK5206-1BC00-2AF26GK5208-0BA00-2AF2product type designationSCALANCE XF204SCALANCE XF204-2SCALANCE XF206-1SCALANCE XF208transfer rate    transfer rate10 Mbit/s, 100 Mbit/s10 Mbit/s, 100 Mbit/s10 Mbit/s, 100 Mbit/s10 Mbit/s, 100 Mbit/sinterfaces for communication integrated    number of electrical connections    ● for network components or terminal equipment4468number of 10/100 Mbit/s RJ45 ports integrated● with securing collar4number of 100 Mbit/s ST(BFOC) ports    ● for multimode21interfaces other    number of electrical connections    ● for signaling contact1111● for power supply1111type of electrical connection    ● for signaling contact2-pole terminal block2-pole terminal block2-pole terminal block2-pole terminal block● for power supply4-pole terminal block4-pole terminal block4-pole terminal block4-pole terminal blockdesign of the removable storage    ● C-PLUGYesYesYesYessignal inputs/outputs    operating voltage of the signaling contacts    ● at DC rated value24 V24 V24 V24 Voperational current of the signaling contacts    ● at DC maximum0.1 A0.1 A0.1 A0.1 Asupply voltage, current consumption, power loss    product component connection for redundant voltage supplyYesYesYestype of voltage 1 of the supply voltageDCDCDCDC● supply voltage 1 rated value24 V24 V24 V24 V● power loss [W] 1 rated value2.64 W5.28 W4.08 W3.12 W● supply voltage 1 rated value18 ... 32 V18 ... 32 V18 ... 32 V18 ... 32 V● consumed current 1 maximum0.11 A0.22 A0.17 A0.13 A● type of electrical connection 1 for power supply4-pole terminal block4-pole terminal block4-pole terminal block4-pole terminal block● product component 1 fusing at power supply inputYesYesYesYes● fuse protection type 1 at input for supply voltage1.1 A / 33 V1.1 A / 33 V1.1 A / 33 V1.1 A / 33 Vambient conditions    ambient temperature    ● during operation-40 ... +60 °C-40 ... +60 °C-40 ... +60 °C-40 ... +60 °C● during storage-40 ... +70 °C-40 ... +70 °C-40 ... +70 °C-40 ... +70 °C● during transport-40 ... +70 °C-40 ... +70 °C-40 ... +70 °C-40 ... +70 °C● noteIf the IE-Switch XF-200 is installed horizontally, a maximum ambient temperature of +40 °C is permittedIf the IE-Switch XF-200 is installed horizontally, a maximum ambient temperature of +40 °C is permittedIf the IE-Switch XF-200 is installed horizontally, a maximum ambient temperature of +40 °C is permittedIf the IE-Switch XF-200 is installed horizontally, a maximum ambient temperature of +40 °C is permittedrelative humidity    ● at 25 °C without condensation during operation maximum95 %95 %95 %95 %protection class IPIP20IP20IP20IP20design, dimensions and weights    designFlatFlatFlatFlatwidth75 mm75 mm75 mm75 mmheight125 mm125 mm125 mm125 mmdepth73 mm73 mm73 mm73 mmnet weight0.25 kg0.25 kg0.25 kg0.25 kgfastening method● 35 mm top hat DIN rail mountingYesYesYesYes● wall mountingNoNoNoNo● S7-300 rail mountingNoNoNoNo● S7-1500 rail mountingNoNoNoNoproduct features, product functions, product components general    cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s50100100100cascading in cases of star topologyany (depending only on signal propagation time)any (depending only on signal propagation time)any (depending only on signal propagation time)any (depending only on signal propagation time)product functions management, configuration, engineering    product function    ● CLIYesYesYesYes● web-based managementYesYesYesYes● MIB supportYesYesYesYes● TRAPs via emailYesYesYesYes● configuration with STEP 7YesYesYesYes● port mirroringYesYesYesYes● multiport mirroringNoNoNoNo● with IRT PROFINET IO switchNoNoNoNo● PROFINET IO diagnosisYesYesYesYesPROFINET conformity classBBBBproduct function switch-managedYesYesYesYesprotocol is supported    ● TelnetYesYesYesYes● HTTPYesYesYesYes● HTTPSYesYesYesYes● TFTPYesYesYesYes● FTPYesYesYesYes● BOOTPNoNoNoNo● DCPYesYesYesYes● LLDPYesYesYesYes● SNMP v1YesYesYesYes● SNMP v2YesYesYesYes● SNMP v3YesYesYesYesidentification & maintenance function 河南西门子PLC总代理   ● I&M0 - device-specific informationYesYesYesYes● I&M1 – higher level designation/location designationYesYesYesYesproduct functions diagnostics    product function    ● port diagnosticsYesYesYesYes● statistics Packet SizeYesYesYesYes● statistics packet typeYesYesYesYes● error statisticsYesYesYesYesproduct functions DHCP    product function    ● DHCP clientYesYesYesYesproduct functions redundancy    product function    ● ring redundancyYesYesYesYes● High Speed Redundancy Protocol (HRP)YesYesYesYes● high speed redundancy protocol (HRP) with redundancy managerYesYesYesYes● high speed redundancy protocol (HRP) with standby redundancyNoNoNoNoprotocol is supported Media Redundancy Protocol (MRP)YesYesYesYesproduct function    ● media redundancy protocol (MRP) with redundancy managerYesYesYesYes● Parallel Redundancy Protocol (PRP)/operation in the PRP-networkYesYesYesYes● Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)NoNoNoNo● passive listeningYesYesYesYesproduct functions security    protocol is supported    ● SSHYesYesYesYesproduct functions time    product function    ● SICLOCK supportYesYesYesYesprotocol is supported    ● NTPNoNoNoNo● SNTPYesYesYesYesstandards, specifications, approvals    standard    ● for FMFM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4● for safety from CSA and ULUL 60950-1, CSA C22.2 No. 60950-1UL 60950-1, CSA C22.2 No. 60950-1UL 60950-1, CSA C22.2 No. 60950-1UL 60950-1, CSA C22.2 No. 60950-1● for emitted interferenceEN 61000-6-4:2001 (Class A)EN 河南西门子PLC总代理61000-6-4:2001 (Class A)EN 61000-6-4:2001 (Class A)EN 61000-6-4:2001 (Class A)● for interference immunityEN 61000-6-4:2001EN 61000-6-2:2001EN 61000-6-2:2001EN 61000-6-2:2001MTBF48.03 y43.58 y43.52 y54.8 yreference code    ● according to IEC 81346-2KFKFKFKF● according to IEC 81346-2:2019KFEKFEKFEKFEstandards, specifications, approvals CE    certificate of suitability CE markingYesYesYesYesstandards, specifications, approvals hazardous environments    standard for hazardous zoneEN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 XEN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 XEN 60079-0: 2006, EN60079-15: 2005, II 3 (2) G Ex nA [op is] IIC T4, KEMA 07 ATEX 0145 XEN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X● from CSA and ULANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4certificate of suitability    ● CCC for hazardous zone according to GB standardYesYesYesYes● for cULus HazLoc as File Nr.E240480 (NWHP, NWHP7)E240480 (NWHP, NWHP7)E240480 (NWHP,河南西门子PLC总代理 NWHP7)E240480 (NWHP, NWHP7)standards, specifications, approvals other    certificate of suitabilityEN 61000-6-4:2001EN 61000-6-2:2001, EN 61000-6-4:2001EN 61000-6-2:2001, EN 61000-6-4:2001EN 61000-6-2:2001, EN 61000-6-4:2001● C-TickYesYesYesYes● KC approvalYesYesYesYes● railway application in accordance with EN 50155NoNoNoNo● railway application in accordance with EN 50124-1NoNoNoNostandards, specifications, approvals marine classification    Marine classification association    ● American Bureau of Shipping Europe Ltd. (ABS)YesYesYesYes● French marine classification society (BV)YesYesYesYes● Det Norske Veritas (DNV)NoNoNoNo● Germanische Lloyd (GL)NoNoNoNo● DNV GLYesYesYesYes● Lloyds Register of Shipping (LRS)YesYesYesYes● Nippon Kaiji Kyokai (NK)YesYesYesYes● Polski Rejestr Statkow (PRS)NoYesYesYes● Royal Institution of Naval Architects (RINA)YesYesYesYesaccessories    product extension optional C-PLUGYes河南西门子PLC总代理

3114789836_small.jpg

More information

You can order supplementary components for the SIMATIC NET cabling range from your local contact. Technical support on this subject is available from:

J. Hertlein河南西门子PLC总代理DI PA DCP IWA
Tel.: +49 (172) 3172810 
Email: juergen.hertlein@siemens.com

Selection Tool:

To support the selection of SCALANCE network components, the TIA Selection Tool is available at:

www.siemens.com/tst

Ordering overview:

You can find more information on the FastConnect range in the "Cabling technology for communication networks in industry" ordering overview.

All about SCALANCE XF-200 switches