西门子PLC模块代理商上海一级代理
由于PLC具有上述特点,使得PLC的应用范围*为广泛,可以说只要有工厂、有控制要求就会有PLC的应用。
1.1.3 PLC的分类
PLC是应现代化生产的需要而产生的,PLC的分类也必然要符合现代化生产的需求。一般来说,可以从3个角度对PLC进行分类,即控制规模、控制性能、结构特点
The managed Industrial Ethernet switches of the SCALANCE XP-200 product line with 8 or 16 Ethernet ports are optimally suited for setting up cabinet-free automation concepts of Industrial Ethernet networks with transmission rates of 10/100/1 000 Mbps in a line, star or ring topology.
Integral redundancy manager for configuration of high availability networks in ring topologies
Electric device or network connection西门子PLC模块代理商上海一级代理
Rugged metal enclosure with mounting options on SIMATIC ET 200pro rack, ITEM rail mounting or direct wall mounting
Rugged device connections with industrial-strength M12 plug connectors, M12 D-coded for FastEthernet (10/100 Mbps interfaces), M12 X-coded for Gigabit (1 000 Mbps interfaces), PROFINET and EtherNet/IP-compliant M12 connection technology (M12 D-coded, M12 X-coded)
Redundant power supply (M12, A-coded)
Console port (M12, D-coded)
Diagnostics on the device by means of prominent LED display with integrated SELECT/SET button (power, link status, data traffic, display mode)
Integration into the SINEC NMS network management system for end-to-end network diagnostics with central firmware management
Error signaling contact with easy adjustment using SELECT/SET button. Configuration storage using the C-PLUG removable data storage medium
Grounding screw for external ground connection
Virtual Local Area Network (VLAN) port-based, protocol-based and IP-based
IGMP snooping und query (use in EtherNet/IP networks)
Access Control List (ACL) MAC-based and IP-based
Link aggregation西门子PLC模块代理商上海一级代理
Standby observer for HRP
IEEE 802.1X (e.g. RADIUS)
Rapid Spanning Tree Protocol/Multi Spanning Tree Protocol (RSTP/MSTP)
Remote Network Monitoring (RMON)
Configuration in the TIA Portal as well as in web-based management (WBM)
H-Sync for implementation of system redundancy together with a SIMATIC S7-1500R
The XP-200EEC versions are also optimized for use in process automation and feature the following properties:
Conformal coating PCBs
Max. installation altitude 4000 m
Extended temperature range from -40 °C to +70 °C
NAMUR NE 21-compliant
Firmware support for S2 device and CiR/H-CiR
Release and integration capability for SIMATIC PCS 7
Product variants
For use in PROFINET and EtherNet/IP automation systems, device variants are offered that have a corresponding default setting for the respective automation system. However, the use of a device with a PROFINET or EtherNet/IP default setting is possible in the other network at any time by changing the configuration.
Switches with PROFINET delivery state
SCALANCE XP208西门子PLC模块代理商上海一级代理
With eight electrical ports (10/100 Mbps, M12 D-coded) for mounting outside the control cabinet (IP65)
SCALANCE XP208EEC
With eight electrical ports (10/100 Mbps, M12 D-coded) for mounting outside the control cabinet (IP65). Equipped with conformal coating PCBs for use with increased environmental requirements, e.g. rail applications (EN 50155/45545)
SCALANCE XP208PoE EEC
With four electrical ports (10/100 Mbps, M12 D-coded) and four electrical PoE ports (10/100 Mbps M12 D-coded) according to IEEE 802.3at type 2 for mounting outside the control cabinet (IP65). Equipped with conformal coating PCBs for use where increased environmental requirements prevail, e.g. rail applications (EN 50155/45545)
SCALANCE XP216
With twelve electrical ports (10/100 Mbps, M12 D-coded) and 4 electrical ports (10/100/1 000 Mbps, M12 X-coded) for mounting outside the control cabinet (IP65)
SCALANCE XP216EEC
With twelve electrical ports (10/100 Mbps, M12 D-coded) and 4 electrical ports (10/100/1 000 Mbps, M12 X-coded) for mounting outside the control cabinet (IP65). Equipped with conformal coating PCBs for use where increased environmental requirements prevail, e.g. rail applications (EN 50155/45545)
SCALANCE XP216PoE EEC
With eight electrical ports (10/100 Mbps, M12 D-coded), six electrical PoE ports (10/100 Mbps, M12 D-coded) according to IEEE 802.3at type 2, and two electrical PoE ports (10/100/1 000 Mbps, M12 X-coded) according to IEEE 802.3at type 2. The switch can also be operated with only two PoE ports (10/100 Mbps, M12 D-coded) according to IEEE 802.3at type 2 and two PoE ports (10/100/1 000 Mbps, M12 X-coded) according to IEEE 802.3at type 2. The switch is designed for mounting outside the control cabinet (IP65), and is equipped with conformal coating PCBs for use where increased environmental requirements prevail, e.g. rail applications (EN 50155/45545)
Switches with EtherNet/IP delivery state
Benefits西门子PLC模块代理商上海一级代理Ideal solution for configuring Industrial Ethernet line, star and ring topologies
Industrial-grade plug-in connection (10/100 Mbps M12, D-coded and 10/100/1 000 Mbps, X-coded)
High network availability through configuration of redundant ring topologies (redundancy manager integrated)
Integration of SCALANCE XP-200 Industrial Ethernet switches in existing network management systems (e.g. SINEC NMS) through SNMP access
Easy integration in the process diagnostics and system diagnostics with PROFINET and EtherNet/IP
Integrated configuration and diagnostics in STEP 7/TIA Portal bring significant advantages during the engineering, commissioning, and operating phases of a plant
C-plug enables fast device replacement in the event of an error
Integration of switches in systems with simple S2 system redundancy and Configuration in Run (CiR/HCiR)
Since Configuration in Run (CiR/H-CiR) is supported, PROFINET-defined configuration changes to the switch are performed during operation
Easy integration in the process and system diagnostics with PROFINET via SIMATIC PCS 7
ApplicationThe SCALANCE XP-200 Industrial Ethernet switches enable cost-effective configuration of Industrial Ethernet line, star or ring topologies with switching functionality for networks in which high availability or remote diagnostic capabilities are required.
Features:西门子PLC模块代理商上海一级代理
Industry-compatible thanks to rugged metal housing (e.g. for use in rail applications with increased mechanical loads)
Use outside the control cabinet also possible (IP65 degree of protection)
Various mounting options (SIMATIC ET 200pro rack, ITEM rail mounting, wall mounting)
Versatile diagnostic and management capabilities: e.g. signaling contact, remote access via SNMP, web-based management and integrated diagnostics with PROFINET and EtherNet/IP
Use in rail applications thanks to EN 50155 and EN 45545 approval and conformal coating PCBs
Use in harsh ambient conditions (-40 °C to +70 °C)
Installation altitudes up to 4 000 m
Firmware support of: S2 device and CiR/H-CiR. The devices are released for SIMATIC PCS 7 and are integration-capable
Design西门子PLC模块代理商上海一级代理The SCALANCE XP-200 Industrial Ethernet switches with rugged metal enclosure are optimized for use outside the control cabinet. Mounting options on ET 200pro rack, ITEM rail mounting or direct wall mounting in variety of mounting positions.
The switches with IP65 degree of protection feature:
Two 4-pole M12 connections (A-coded) for connection of redundant supply voltage (2 x 24 V DC)
An LED display for display of status information using SELECT/SET button (power, link status, data traffic, power supply, signaling contact)
One 2-pole M12 interface (B-coded) for connecting the floating signaling contact
One 2-pole M12 interface (D-coded) as console access
The SCALANCE XP-200 switches are available with the following port types:
10/100 Mbps, M12 connection (D-coded);
automatic detection of the data rate (10 or 100 Mbps), with autosensing and autocrossover function for connection of IE FC cables via IE FC M12 plug PRO 2x2 up to 100 m.
10/100/10 000 Mbps, M12 connection (X-coded);
automatic detection of the data rate (10 or 100 or 1 000 Mbps), with autosensing and autocrossover function for connection of IE FC cables via IE FC M12 plug PRO 4x2 up to 100 m.
Configuration of electrical Industrial Ethernet line, star and ring topologies
Fast redundancy in the ring with:
High Speed Redundancy Protocol (HRP); up to 0.3 seconds for reconfiguration of the ring with 50 switches in the ring
PROFINET MRP (Media Redundancy Protocol); up to 0.2 seconds for reconfiguration of the ring with 50 switches in the ring
The functioning of the ring is continuously monitored by the integrated redundancy manager. It recognizes failure of a transmission link in the ring or failure of a SCALANCE XP-200 and activates the substitute path within 0.3 seconds with HRP or 0.2 seconds with MRP
Use in ring topologies together with SCALANCE X-200, X-300, XM-400 and XR-500
Redundant connection of rings via HRP standby master/slave function
Uncrossed connecting cables can be used due to autocrossover function integrated in the ports
Easy diagnostics using signaling contact, SNMP and web browser
Easy copper cable diagnostics via web browser for localizing cable breaks
Incorporation in the integrated system diagnostics of the TIA Portal with PROFINET diagnostics of data traffic using a configurable mirror port and a commercially available network analyzer (e.g. via BUSANALYZER AGENT XM-400)
Optimized support of PROFINET real-time communication (RT) through prioritizing
Fast device replacement in the event of a fault by using the optional C-plug removable data storage medium (not included in scope of delivery)
Network topology and network configuration西门子PLC模块代理商上海一级代理
The SCALANCE XP-200 Industrial Ethernet switches in IP65 degree of protection are typically mounted outside the control cabinet. They can be installed in line, star and ring electrical system topologies.
When configuring the network, the following boundary conditions must be observed:
Length of the twisted pair line between two SCALANCE X Industrial Ethernet switches:
Max. 100 m with IE FC cable and IE FC M12 plug PRO
IP address:西门子PLC模块代理商上海一级代理
The IP address is assigned via the DHCP (Dynamic Host Configuration Protocol). If there is no corresponding server in the network, the IP address can be assigned using the supplied software tool PST (Primary Setup Tool) or STEP 7/TIA Portal.
SCALANCE XP208 and SCALANCE XP216 in factory automation
SCALANCE XP208EEC and SCALANCE XP216EEC on trains (train-side) and along the track (track-side)
Implementation of a network in a harsh environment with SCALANCE XP208EEC and SCALANCE XP216EEC for communication of distributed stations with WIMAX base
Commissioning and diagnostics
PROFINET diagnostic interrupts from SCALANCE XP-200 switches can be displayed with the appropriate SIMATIC engineering tools and processed in the PLC with the enhanced diagnostic function. The engineering outlay for the PLC and HMI has been drastically reduced due to the complete integration in the SIMATIC concept for system error messages.
SCALANCE XP-200 Industrial Ethernet switches can also be integrated in a network management system (e.g. SINEC NMS) using the standardized Simple Network Management Protocol (SNMP). In the event of faults in the device, error messages (SNMP traps) can be sent to a network management system (e.g. SINEC NMS) or as an email to a specified network administrator.
The integrated web server enables configuration and diagnostics settings to be made using a standard web browser (e.g. port configuration). Statistical information can also be read out over the web server (e.g. port capacity utilization).
The following information is displayed on site by LEDs:
Power
Port status
Data traffic
Signaling contact
Redundancy manager function
The Industrial Ethernet switches of the SCALANCE XP-200 line can also be monitored using the floating signaling contact.
Cabinet-free use of Industrial Ethernet switches on the machine itself with SCALANCE XP-200
因为这些都是作为PLC的接口设备接到PLC端口上去的,它们的状态与PLC程序是息息相关的。但是,从程序要求来看,没有必要去专门先学习这方面的课程,而是应该是用到就学、边学边用。待到一定程度后,再系统地学习一下,效果会*好。辑代数是从数学的角度来研究客观事物“真”与“假”之间的逻辑推理关系。在继电控制和PLC多学员都有这样的感觉,当从事某一项新的工作时,总感到自己缺乏系统的理论知识和丰富的实践知识。那么怎么办?一个字:学。理论知识可以系统地学,学习之前,应向周围的同行、同事去问一下,应学习哪些知识,有哪些书可以阅读,有没有系统的培训等。这样可以少走弯路,*学要还是靠自己。PLC的输入/输出系统功能完善,性能可靠,能够适应各种形式和性质的开关量和模拟量的输入/输出。PLC的功能单元能方便地实现D/A、A/D转换以及PID运算,实现过程控制、数字控制等功能。它还可以和其他计算机系统、控制设备共同组成分布式或分散式控制系统,能够很好地满足各种控制的需要。
5.设计、施工、调试的,维护方便西门子PLC模块代理商上海一级代理
继电器接触器控制系统中的中间继电器、时间继电器、计数器等电器元件,在PLC控制系统中是以“软元件”形式出现的,并且又用程序代替了硬接线,因此安装接线工作量少;工作人员也可提前根据具体的控制要求在PLC到货之前进行编程,大大地缩短了施工工期。
PLC体积小、重量轻,便于安装。PLC具有完善的自诊断及监视等功能,对于其内部的工作状态、通信状态、I/O点状态、异常状态和电源状态都有显示。工作人员通过它可以查出故障原因,便于迅速处理。
。西门子PLC模块代理商上海一级代理